TS3000 Series Firmware Updater for Windows Version 1.92 Name TS3000 Series Firmware Updater for Windows Version 1.92 File ts3000-v192.zip Size 390,043,548 Bytes Date November 20, 2019 Platform Windows PC OS Windows 10 (64- and 32-bit), 8.1 (64- and 32-bit), 8 (64- and 32-bit), 7 (64- and 32-bit), Vista (64- and 32-bit), XP Windows Server 2012, 2008, 2003 Models TS3200D, TS3400D, TS3400R Copyright Buffalo Inc. Distribution .ZIP archive Condition Re-distribution is not allowed. Manuals Quick setup guide, user manual This product uses GPL/LGPL applicable software and you are welcome to keep, modify, and redistribute the source code. Please ask our technical support representatives about modified GPL, applicable modules, and how to deliver them. You may be charged for the delivery cost. [Software Description] This software will update the TS3000 series TeraStation’s firmware to version 1.92. If your unit’s firmware is already version 1.92 or later, you don’t need this update. [How to Confirm the Firmware Version] Select your TeraStation from NAS Navigator2. The firmware version is displayed on the bottom right corner of the window. [Before Updating the Firmware] • Please consult your local technical support representative if you experience any problems caused by this firmware update. • Do not turn off the TeraStation until the firmware update is completed and the “finished” message is displayed. • USB drives may not be mounted automatically after updating the firmware. To mount them, unplug and then reconnect them. [How to Update the Firmware] 1. Connect the TeraStation and a computer to run the updater on the same network subnet. The subnet masks should be the same and the first three numbers of the IP addresses should be the same. The last number of the IP addresses should be different. For example, if the IP address and subnet mask of the computer are “192.168.0.10/255.255.255.0” and the IP address and subnet mask of the TeraStation are “192.168.1.150/255.255.255.0”, then the updater will not work properly. In this case, reconfigure the TeraStation’s IP address and subnet mask to “192.168.0.150/255.255.255.0”. Then they will be on the same subnet and the updater will work properly. 2. Exit all applications. Also, stop or exit any firewall software. 3. Extract the downloaded file and run “TSUpdater.exe”. When a TeraStation is detected, an update window will open. 4. If multiple TeraStations are connected to the network, select which TeraStation to update. 5. Click ‘Update’ and enter the TeraStation’s admin password. 6. Click ‘OK’. 7. It will take several minutes for the firmware to update. During the update process, the info LED will blink. Don’t disconnect or power down the TeraStation until the update is finished. 8. When the update is finished, a message will be displayed. [Firmware Release Notes] Version 1.92 [2019.11.20] Bug Fixes [System] • Modified to patch vulnerabilities (CVE-2018-13318, CVE-2018-13319, CVE-2018-13320, CVE-2018-13321, CVE-2018-13322, CVE-2018-13323, and CVE-2018-13324). Due to this change, you will be required to enter the username and password for certain actions, even when opening Easy Admin. Version 1.91 [2019.1.16] Bug Fixes [System] • Fixed a bug where a temperature error was erroneously detected if the S.M.A.R.T. information could not be acquired. Version 1.90 [2018.6.19] Added and Modified Features [Amazon S3] • Modified so that a region can be selected when configuring settings with Amazon S3. If you can’t access a bucket and its region is blank, try configuring the region. • Modified so that unexpected downloads do not occur after the cloud storage service is disabled and then enabled. Bug Fixes [Backup] • Fixed a bug where a backup error was not displayed when the backup job was canceled due to any settings changes made while the backup job was running. [Amazon S3] • Fixed a bug where an backup error occurred when backup was enabled. • Fixed a bug where the upload speed may become slow when Amazon S3 is configured. Version 1.85 [2018.4.25] Added and Modified Features [SNMP] • MIB objects have been added to show the date when the error or information events occurred based on the configured time zone on the MIB browser. • MIB objects have been added to use the same unit that the TeraStation’s Settings uses for total and used capacities of drives and LVM volumes on the MIB browser. Bug Fixes [SMB] • Modified to deal with a Samba programming vulnerability (CVE-2017-12150, CVE-2017-12163). Version 1.84 [2018.1.18] Bug Fixes [SMB] • Modified to deal with a Samba programming vulnerability (CVE-2017-15275). Version 1.83 [2017.11.16] Bug Fixes [Replication] • Fixed a bug where a replication error occurs when disconnecting and reconnecting the USB drive after replication task was created. [NFS] • Fixed a bug where the TeraStation could not be accessed from specific NFS clients. [Email Notifications] • Fixed a bug where the email notification settings were configured properly even if a test email failed to be sent. [System] • Fixed a bug where the SMB log did not rotate. • Fixed a bug where a NAS API error occurs and creating a backup task fails after applying settings from a USB drive. [Backup] • Fixed a bug where the TeraStation could not be detected when configuring backup on another TeraStation if too many users and/or groups were added for access restrictions. • The backup target folder for a backup job where a different TeraStation is the backup source has been changed to “backup target folder”/“date”/“backup source folder”. [Settings] • Fixed a bug where access restrictions for shared folders could not be configured by a power user via Easy Admin. • Improved security. [Failover] • Fixed a bug where configuring failover failed. • Fixed a bug where a failover error message was displayed when canceling the maintenance mode if the TeraStation has too many files. [SMB] • Fixed a bug where the access-restricted folder reserved for admin users could not be accessed after initializing settings. Version 1.82 [2017.6.19] Bug Fixes [SMB] • Modified to deal with a Samba programming vulnerability (CVE-2017-7494). Version 1.81 [2017.6.5] Bug Fixes [UPS] • Fixed a bug where the TeraStation may have stopped working if a UPS device was connected. Version 1.80 [2017.5.8] Bug Fixes [Replication] • Modified to use a backup device access key for a replication task. This access key is the same as the backup key that has already been used. [Failover] • Improved the security level. Version 1.71 [2017.3.28] Bug Fixes [System] • Fixed a bug where the TeraStation was disconnected from the network if a shared folder on this TeraStation was configured as a destination for saving recording data for the surveillance camera. [Failover] • Fixed a bug where newly-created folders or files saved on the main TeraStation could not be copied to the backup TeraStation and the backup unit did not replace the main unit properly. [UPS] • Fixed a bug where the E10 error message kept displaying if a specific UPS device was connected by a serial cable. [Antivirus] • Fixed a bug where antivirus became disabled when waking up from sleep mode. [Settings] • Fixed a bug where the username was displayed on the “Email Address” box when verifying the user account information. • Fixed a bug where the “Confirm Operation” window appeared corrupted on certain browsers. Version 1.70 [2016.8.16] Bug Fixes [ImageMagick] • Modified to deal with an ImageMagick filtering vulnerability (CVE-2016-3714). [Bash] • Modified to deal with Bash programming vulnerabilities (CVE-2014-7186 and CVE-2014-7187). [OpenSSL] • Modified to deal with OpenSSL programming vulnerabilities (CVE-2016-2176, CVE-2016-2109, CVE-2016-2108, CVE-2016-2107, CVE-2016-2106, and CVE-2016-2105). [Samba] • Modified to deal with Samba programming vulnerabilities, including Badlock vulnerability (CVE-2016-2112, CVE-2016-2115, CVE-2016-2118, CVE-2016-2110, CVE-2016-2111, CVE-2015-5370, CVE-2016-2113, CVE-2016-2114, CVE-2015-5252, CVE-2015-5296, CVE-2015-5299, and CVE-2015-7560). [lighttpd] • Modified to deal with lighttpd programming vulnerabilities (CVE-2013-4559 and CVE-2014-2323). [System] • Fixed a bug where a working drive was erroneously identified as malfunctioning. • Fixed a bug where the size at “Size on disk” were displayed larger than actual size when referring the files in the TeraStation on Windows 8.1 or later. [Settings] • Fixed a bug where Settings could not be accessed. [Configuration Migration] • Fixed a bug where migrating settings from TS-XHL series failed. [Email Notifications] • Fixed a bug where blank emails were sent. • Fixed a bug where some notification emails were detected as spam by a mail server. As a countermeasure for this bug, the “Sender Address” field has been added to the email notification settings page in Settings. [UPS] • Changed to have the E10 error display when the connection between the TeraStation and the UPS could not be established. [Quotas] • Fixed a bug where up to 2047 GB were allotted as the quota size. [Samba] • Fixed a bug where a trashbox folder was set to “.recycle”, not “trashbox” and the created “.recycle” folder could not be deleted. The “.recycle” folder can now be deleted by clicking ‘Empty Recycle Bin’ from Settings after updating the firmware to this version. [NFS] • Fixed a bug where the shared folder selection window was not displayed properly when adding NFS rule if multiple shared folder with NFS enabled were created. [FTP] • Fixed a bug where the TeraStation could not be accessed via FTP after configuring access restrictions with a group that includes a specific number of members, then restarted. [Workgroup/Domain] • Fixed a bug where domain users could not access shared folders if the group that these domain users joined is configured for access restrictions. [Network] • Fixed a bug where default gateway and DNS settings were cleared when disconnecting and reconnecting the Ethernet cable. • Fixed a bug where Wake-on-LAN did not work when disconnecting and reconnecting the power cable after the shutdown. [Services] • Fixed a bug where music files did not recognized if a subfolder that contains a space in its folder name was configured as iTunes public folder. Version 1.60 [2016.4.14] Added and Modified Features [iSCSI] • Modified to display clients connecting to the volumes when displaying the connection history. You can see it by navigating to ‘Drives’ - ‘iSCSI’ and click ‘Show Active Connections’ on Settings. Bug Fixes [Amazon S3] • Fixed a bug where while on the AWS Management Console, renamed or uploaded files did not appear on the TeraStations. • Fixed a bug where Amazon S3 did not work if drive 1 fails while Amazon S3 was enabled. [Others] • Fixed a bug where an error message was displayed when accessing the shared folder settings for a shared folder that has access restrictions enabled for local users. Version 1.50 [2016.2.24] Added and Modified Features [SNMP] • Modified to support SNMPv3. • Modified so that more of the following settings can be acquired via SNMP protocol: ◦ Model name ◦ Firmware version ◦ Serial number ◦ Checking whether newer firmware is released ◦ Showing whether the function status is enabled or disabled ◦ S.M.A.R.T. for each drive Update the MIB file on your SNMP client software to the latest version. You can download the MIB file from the Buffalo website. [OpenSSL] • Updated OpenSSL to the latest version. [Email Notifications] • Modified so that the report categories and when the email will be sent are now configurable. The current settings will be taken over by the firmware update but we recommend verifying if the function works properly after the firmware update. • S.M.A.R.T information is now available to be sent via the notification email. It can be configured from “Advanced Report Settings”. Bug Fixes [Failover] • Fixed a bug where failover could not be canceled temporarily if an online update notice is present. [Email Notification] • Fixed a bug where authentication settings were kept even if authentication was disabled. [UPS Sync] • Fixed a bug where the E10 error occurred when specific settings were changed without first connecting the UPS to the TeraStation. [Settings] • Fixed a bug where Settings could not be accessed. • Fixed a bug where the status of a spare drive shows an error during bootup. • Fixed a bug where the CPU became overloaded when a test email was sent using the wrong settings. [USB Drive] • Fixed a bug where files that contain multibyte characters in the filename could not be accessed when they were stored in NTFS-formatted USB drives. [Samba] • Fixed a bug where the access-restricted folder reserved for admin users cannot be accessed after initializing settings. Version 1.41 [2015.9.3] Bug Fixes [USB Drive] • Fixed a bug where some USB drives were not recognized by the TeraStation. Version 1.40 [2015.7.30] Bug Fixes [Configuration Management] • Fixed a bug where the Omron UPS was not recognized properly when using a D-sub 9-pin connector. [Replication] • Improved the reliability of replication. • Fixed a bug where the TeraStation became slower when accessing the replication source shared folder via FTP. • Fixed a bug where replication errors may occur when both virus scan and replication were enabled. [File Sharing] • Fixed a bug where any users and groups could access an access-restricted shared folder if the folder’s access restriction settings were set to no access. Since this firmware update, it is modified so that only admin users and groups can access the folder. Version 1.30 [2015.6.4] Added and Modified Features • TS-X series TeraStations now support the settings transfer feature. • Configuration migration now supports config files (.nas_config) that are password-protected. Bug Fixes [Configuration Migration] • Fixed a bug where protocols other than SMB were enabled on the migration target TeraStation if the migration source enabled Hidden Share and transfered the setting. • Fixed a bug where access restrictions that were disabled before settings transfer became enabled. • Fixed a bug where no error messages were displayed when the number of registrable shared folders, users, and groups reaches the maximum. • Modified the error message when the migration target TeraStation joins a different domain network environment than the one saved in the config file. • Modified the error message when the network disconnected while transferring settings. • Modified the error message when the config file could not be loaded. [Network] • Fixed a bug where access restrictions with domain users reverted to “disabled” after restarting the unit. Version 1.20 [2015.4.6] Added and Modified Features • Added feature to transfer settings from TS-HTGL/R5 series TeraStations (as of March 2015). Bug Fixes • Modified to deal with Samba programming vulnerabilities (CVE-2015-0240 and CVE-2014-0178). Version 1.16 [2015.1.14] Added and Modified Features [Settings] • OS X 10.10 is now supported. Bug Fixes [Network] • Modified to deal with the OpenSSL programming vulnerabilities (CVE-2014-3567 and CVE-2014-3568) that are also know as the POODLE (SSL 3.0) vulnerability. Version 1.15 [2014.11.28] Bug Fixes [System] • Fixed a bug where a service that sent email notifications did not run. • Fixed a bug where NTP sync did not work. • Fixed a bug where user was not informed of an available online update. • Fixed a bug where S.M.A.R.T information could not be obtained. • Fixed a bug where a scheduled RAID scan did not run. • Fixed a bug where sleep timer did not run. • Fixed a bug where a scheduled backup did not run. Version 1.14 [2014.10.21] Bug Fixes and Modified Features [System] • Modified to resolve Bash programming vulnerabilities which allow remote attackers to execute arbitrary commands (CVE-2014-6271 and CVE-2014-7169). • Improved so that services do not stop when connecting/disconnecting USB devices. • Fixed a bug where email notifications sent the same two emails after the firmware updates. • Fixed a bug where port-trunked devices could not be selected for surveillance server. • Fixed a bug where some settings were not copied during failover. • Improved log messages in the SMB access logs. • Added CPU and memory utilization to system information list. [Replication] • Improved replication reliability. • Fixed a bug where the I33 message was displayed in Settings, NAS Navigator2, and on the LCD panel even though replication was not configured. Version 1.13 [2014.8.21] Bug Fixes and Modified Features [Backup and Replication] • Fixed a bug where a backup job failed if too many files were backed up at once. • Fixed a bug where a backup job could not be registered if the destination folder contains a multibyte space in its folder name. • Removed the Windows backup option from the shared folder settings page. Using Windows server to back up to the TeraStation no longer requires additional configuration. • Fixed a bug where a backup job failed if a shared folder in a LVM volume is configured as a backup source. • Fixed a bug where the TeraStation on a different network could not be configured as replication target. • Fixed a bug where the TeraStation did not respond if too many backup jobs were configured or deleted at the same time. • Fixed a bug where Amazon S3 folder was not displayed as a backup target. [Amazon S3] • Fixed a bug where file copying failed if too many files were copied at once. • Fixed a bug where downloading failed if the downloaded file is 2 GB or larger. • Fixed a bug where the connection status didn’t show “Error” when a connection error occurred. • Fixed a bug where invalid events were logged. [Network] • Fixed a bug where joining Active Directory may sometimes fail. • Modified to configure IP address, subnet mask, default gateway, and DNS server from the same settings page. • Fixed a bug where changing the IP address from NAS Navigator2 may not finish properly. [FTP/FTPS] • Fixed a bug where a 10 GB or larger file could not be transferred via FTP. • Fixed a bug where a local user could not access the TeraStation via FTP or SFTP if the TeraStation joined a domain network. [USB] • Fixed a bug where an exFAT-formatted USB hard drive disappeared if disk check was run on it. • Fixed a bug where if a file is copied to an exFAT-formatted USB drive, an incorrect character may be displayed in the filename. [Update] • Fixed a bug where the guest account was automatically enabled after the firmware was updated from version 1.11. • Fixed a bug where if settings were restored from the USB memory recovery device, some settings were not restored correctly. [Email Notification] • Improved email notifications for English, Japanese, and German languages. • Fixed a bug where the date in the email header was blank. • Fixed a bug where email notifications failed if the email password contains specific special characters. [Others] • Modified the messages on the LCD display. • Fixed a bug where Direct Copy from the digital camera in PTP mode would fail. • Fixed a bug where an access-limited folder could not be accessed even if a user was allowed to access the folder. • Fixed a bug where the user deletion event was not logged in the system log. • Fixed a bug where NTP settings could not be changed if surveillance server was enabled. • Fixed a bug where users imported from a CSV file did not join the “hdusers” group. • Improved some UI texts. Version 1.12 [2014.2.7] Bug fixes [System] • In some cases, a failed firmware update could re-partition the drive(s), possibly leading to a loss of user data. This problem has been resolved; the system will no longer replace user partitions. After recovery, user partitions will be undamaged and available. Version 1.11 [2013.11.1] Added and Modified Features [System] • Antivirus scanning is now supported. [Replication] • Encrypting and compressing backup data transfers are now supported. Note: When you use these features, data transfer speeds will be slower. [NFS] • Read-only shared folders are now supported. • Async is now supported in kernel mode. Note: When you update from an older firmware, the default setting is “Async”. To change it to “Sync”, change NFS rules in Settings. [iSCSI] • IQN is now displayed in volume settings in Settings. Bug Fixes [System] • Fixed the bug where data was not saved properly when the power was cut off right after writing the data. • Fixed the bug where settings could be changed from other computers or browsers while the firmware was being updated. • Fixed the bug where TeraStations beeped incorrectly during boot. [RAID] • Fixed the bug where RAID scanning didn’t work on the first day of each month. [Backup] • Fixed the bug where backup jobs failed when multiple files were backed up. [UPS] • Fixed the bug where the E10 error message was incorrectly displayed when an APC UPS went into test mode. Version 1.10 [2013.9.3] Modified Features [System] • TS3200D series is now supported. Bug Fixes [System] • Fixed the bug where applying settings from a USB drive failed when an additional USB drive was connected to the TeraStation. • Fixed the bug where system files were corrupted and the TeraStation failed to boot when all drives were dismounted. • Fixed the bug where TeraStations failed to boot via Wake-on-LAN after unplugging the power cable without shutting the TeraStation down. • Fixed the bug where a drive error was displayed for a hot spare drive when the TeraStation was rebooted. • Fixed the bug where failover was not configured properly from the backup TeraStation’s Settings. • Fixed the bug where “admin” settings couldn’t be changed after settings were initialized. [Backup] • Fixed the bug where a TeraStation could be configured as the management backup target for a TeraStation on another network segment. Version 1.01 [2013.8.7] Bug Fixes • Fixed the NTP automatic time adjustment problem after ‘Management’ - ‘Restore/Erase’ - ‘Initialize TeraStation’ was executed. • Fixed the problem where quota warning emails were not sent after ‘Management’ - ‘Restore/Erase’ - ‘Initialize TeraStation’ was executed. Version 1.00 [2013.7.1] • First release.